| LED | Status | Condition |
| ALARM (red) |
|
Normal condition |
|
|
System in alarm and all alarms have been acknowledged | |
|
|
An alarm condition exists and has not been acknowledged | |
| SUPERVISORY (yellow) |
|
Normal condition |
|
|
Supervisory condition exists on the system | |
|
|
Supervisory condition exists on the system and has not been acknowledged | |
| TROUBLE (yellow) |
|
Normal condition |
|
|
Trouble condition exists on the system | |
|
|
Trouble condition exists on the system and has not been acknowledged | |
| SILENCED (yellow) |
|
Normal condition |
|
|
Alarm or trouble condition has been silenced but condition still exists | |
| AC (green) |
|
Panel is running on AC (normal condition) and the backup battery is fully charged |
|
|
Panel has lost all power | |
|
|
Panel is running on AC power only or backup battery power only | |
| Buttons to Press | Display Message | Enter through Keypad | Comments | ||
|
access code |
The system will perform a display lamp test and a communication test |
|||
| Buttons to Press | Display Message | Enter through Keypad | Comments | ||
|
access code |
Resets system |
|||
| Buttons to Press | Display Message | Enter through Keypad | Comments | ||
|
installer code |
Clears event history of all events |
|||
| Buttons to Press | Display Message | Enter through Keypad | Comments | ||
|
installer code |
Resets the dialer and aborts the report to the monitoring station |
|||
| Buttons to Press | Display Message | Enter through Keypad | Comments | ||
|
installer code |
Will dial the programmed phone number for the computer to initiate an up or download |
|||
| Buttons to Press | Display Message | Enter through Keypad | Comments | ||
|
installer code |
Displays the system history, which includes alarms, supervisories, troubles, reports, time and date changes, etc |
|||
| Buttons to Press | Display Message | Enter through Keypad | Comments | ||
|
access code |
View existing system status. List alarms first, supervisories, and then troubles. |
|||
| Buttons to Press | Display Message | Enter through Keypad | Comments | ||
or
|
|
access code |
|
||
| Buttons to Press | Display Message | Enter through Keypad | Comments | ||
|
access code |
Enter 8 digits for the
date. Example: for 08/31/1999, enter 08311999. Press |
|||
| Buttons to Press | Display Message | Enter through Keypad | Comments | ||
|
access code |
Enter the time in 24 hour format. Example: 2pm is entered as 1400. |
|||
| Buttons to Press | Display Message | Enter through Keypad | Comments | ||
| Zone number
and
|
|
access code |
Repeat the process to enable the re-enable the zone |
||
| Buttons to Press | Display Message | Enter through Keypad | Comments | ||
|
access code |
To end the Fire Drill,
press |
|||
| Buttons to Press | Display Message | Enter through Keypad | Comments | ||
|
access code |
Resets all smoke detector power |
|||
| Buttons to Press | Display Message | Enter through Keypad | Comments | ||
|
installer code |
To end the Walk Test
press |
|||
| Buttons to Press | Display Message | Enter through Keypad | Comments |
| or
|
installer code |
To exit press |
|